This Four Pole breaker is built with Din Railmount to make it easy to install in any industrial setting. This breaker has a max voltage of 240 VAC or 250 VDC and a rated current of 100 Amps. So "staying with Square D brand" does you absolutely nothing unless you stay with QO, which is a costly (but quite good) industrial-tier panel.Schneider Electric Square D BDL46100 B Frame molded case circuit breaker is the perfect combination of performance and features. HOM and QO are 100% incompatible and share nothing except enclosures. And running out of spaces is very costly. Spaces are actually cheap, the cost diff to a "plenty of spaces" panel is pretty minimal. using the most el-cheapo panel on the market, HOMeline. Of course, the "thrifty gene" motivates us to "think cheap" and try to chintz out as much as possible, e.g. The #1 priority when selecting a subpanel is breaker spaces. Forgive yourself the error of "buying before researching", and get the item that's right for you. I already have the HL panel mounted to the wall.ĭon't get swept into the "fallacy of sunk costs", trying to force a wrong thing to work merely because you already own it. If cost was no object or if distance was very short, I'd run 2/0 copper, which is 175A and could actually carry an entire 200A service due to 310.15(B)(7). The largest readily available QO breaker is 125A. The larger wire will allow upgrading the capacity later simply by enlarging the breaker.

square d 100 amp breaker

I'd use the smallest breaker that will do the job for now, since cost is a concern. I think I would run 2/0 aluminum wire (135A) which is the largest wire that will fit on a "QO" 80A through 125A breaker.

square d 100 amp breaker

I'm OK with bring 200A to the sub, but the cost of the QO2225SL subfeed lug will be prohibitive. You implement this feature by choosing EVSE's designed to work with each other via Share2. It dynamically allocates current according to the EVs' needs and abilities. There is even a way for multiple EVs to share a single current allocation, called "Share2". EV charging is actually pretty sophisticated, and they've thought of everything. So if your Load Calculation won't support 80A, you can simply change the commissioning settings on the EVSE to set the current you have available. The Load Calculation will tell you whether the house's service can support all this stuff, and how big subpanels need to be.Įlectric Vehicle charging is adjustable. That is the proper and NEC-specified procedure for determining the load on a panel or service. A Load Calculation is seriously warranted here. Square D Homeline 100 Amp 12-Space 24-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover (HOM1224M100PC) (167) Questions & Answers (93) + Hover Image to Zoom 96 00 Pay 71.00 after 25 OFF your total qualifying purchase upon opening a new card. You would need a QO2225SL subfeed lug kit, with 200A wire to a 200A subpanel. 4 - wire breaker style, new ( 10 ) 100 Amps, Square D, PBPQ4A100, 3. That's perfectly allowed if you want to do it. 100 Amps, Cutler - Hammer, P3BED3100N2, bus plugs 100 Amps, Federal Pacific. So to use a subfeed lug kit, a) the lug kit must be >=200A, b) the wires must be >=200A and c) the subpanel must be >=200A. If your entire service is 200A, rule 310.15(B)(7) kicks in, allowing 4/0 aluminum or 2/0 copper.200A wire is 250 kcmil aluminum or 3/0 copper.So not only must you use a 200A subfeed lug kit, you must use 200A wire. You can't protect 125A wire with a 200A breaker.

square d 100 amp breaker

They too need to be behind breaker protection. The wires beyond the lug kit are in the same situation. The only subfeed lug kit you can use is 200A. Since your main breaker is 200A, and a subfeed lug kit has no breaker, it means a 125A subfeed lug kit is simply not usable in your panel as nothing protects it. It fits where breakers go, but has no breaker. A subfeed lug kit and the wires behind it must be protected by a breaker.Įlectrical equipment and wiring must be protected by a circuit breaker.Ī subfeed lug kit is Square D's name for the thing.